现在的位置: 首页时讯速递, 进展交流>正文
[JAMA Intern Med发表论文]:中心静脉插管的并发症发生率
2024年06月29日 时讯速递, 进展交流 [JAMA Intern Med发表论文]:中心静脉插管的并发症发生率已关闭评论

Original Investigation 

March 4, 2024

Complication Rates of Central Venous Catheters: A Systematic Review and Meta-Analysis

Bijan Teja, Nicholas A. Bosch, Calvin Diep, et al

JAMA Intern Med. 2024;184(5):474-482. doi:10.1001/jamainternmed.2023.8232

Key Points

Question  What are the rates of complications from central venous catheter (CVC) use?

Findings  This systematic review and meta-analysis of literature from 2015 to 2023 found that rates of complications varied substantially across studies, but on average, the rate of serious complications (arterial cannulation, pneumothorax, infection, or deep vein thrombosis) from a CVC placed for 3 days was estimated to be 30 events per 1000 catheters placed (3%). Use of ultrasonography was associated with lower rates of immediate insertion-related complications.

Meaning  This study found that approximately 3% of CVC placements were associated with major complications, with ultrasonography guidance reducing some of the specific risks.

Abstract

Importance  Central venous catheters (CVCs) are commonly used but are associated with complications. Quantifying complication rates is essential for guiding CVC utilization decisions.

Objective  To summarize current rates of CVC-associated complications.

Data Sources  MEDLINE, Embase, CINAHL, and CENTRAL databases were searched for observational studies and randomized clinical trials published between 2015 to 2023.

Study Selection  This study included English-language observational studies and randomized clinical trials of adult patients that reported complication rates of short-term centrally inserted CVCs and data for 1 or more outcomes of interest. Studies that evaluated long-term intravascular devices, focused on dialysis catheters not typically used for medication administration, or studied catheters placed by radiologists were excluded.

Data Extraction and Synthesis  Two reviewers independently extracted data and assessed risk of bias. Bayesian random-effects meta-analysis was applied to summarize event rates. Rates of placement complications (events/1000 catheters with 95% credible interval [CrI]) and use complications (events/1000 catheter-days with 95% CrI) were estimated.

Main Outcomes and Measures  Ten prespecified complications associated with CVC placement (placement failure, arterial puncture, arterial cannulation, pneumothorax, bleeding events requiring action, nerve injury, arteriovenous fistula, cardiac tamponade, arrhythmia, and delay of ≥1 hour in vasopressor administration) and 5 prespecified complications associated with CVC use (malfunction, infection, deep vein thrombosis [DVT], thrombophlebitis, and venous stenosis) were assessed. The composite of 4 serious complications (arterial cannulation, pneumothorax, infection, or DVT) after CVC exposure for 3 days was also assessed.

Results  Of 11 722 screened studies, 130 were included in the analyses. Seven of 15 prespecified complications were meta-analyzed. Placement failure occurred at 20.4 (95% CrI, 10.9-34.4) events per 1000 catheters placed. Other rates of CVC placement complications (per 1000 catheters) were arterial canulation (2.8; 95% CrI, 0.1-10), arterial puncture (16.2; 95% CrI, 11.5-22), and pneumothorax (4.4; 95% CrI, 2.7-6.5). Rates of CVC use complications (per 1000 catheter-days) were malfunction (5.5; 95% CrI, 0.6-38), infection (4.8; 95% CrI, 3.4-6.6), and DVT (2.7; 95% CrI, 1.0-6.2). It was estimated that 30.2 (95% CrI, 21.8-43.0) in 1000 patients with a CVC for 3 days would develop 1 or more serious complication (arterial cannulation, pneumothorax, infection, or DVT). Use of ultrasonography was associated with lower rates of arterial puncture (risk ratio [RR], 0.20; 95% CrI, 0.09-0.44; 13.5 events vs 68.8 events/1000 catheters) and pneumothorax (RR, 0.25; 95% CrI, 0.08-0.80; 2.4 events vs 9.9 events/1000 catheters).

Conclusions and Relevance  Approximately 3% of CVC placements were associated with major complications. Use of ultrasonography guidance may reduce specific risks including arterial puncture and pneumothorax.